ترك رسالة : qiuwenjie@gaoboele.com
هاتف : +86 -17329948916
Manufactured by GAOBO SWITCHGEAR MANUFACTURER, the KYN28-12 metal-clad movable switchgear is a mainstream indoor medium-voltage power distribution device designed for 12kV AC power systems. It stands out in modern power engineering due to its high safety, flexible operability and stable long-term performance.

The core advantages focus on safety and maintainability. Adopting fully armored metal compartment isolation design, the cabinet is divided into independent busbar, breaker, cable and instrument rooms, which effectively blocks arc fault spread and avoids cross-circuit interference. Equipped with a complete five-prevention mechanical interlock system, it thoroughly prevents misoperation such as live switching and accidental grounding, maximizing on-site operational safety. The withdrawable vacuum breaker handcart supports test, isolation and connection positions, enabling fast replacement and front maintenance without cutting off the entire power system, greatly reducing downtime and maintenance costs. In addition, the high-rigidity galvanized steel structure features anti-corrosion and impact resistance, supporting 24-hour continuous heavy-load operation with a long service lifespan.

This versatile switchgear covers a wide range of engineering scenarios. It is widely applied in urban grid substations, industrial parks, manufacturing factories and mining projects for medium-voltage power receiving and distribution. It also perfectly matches infrastructure construction including rail transit, airport facilities, commercial complexes and high-rise buildings. Moreover, it serves new energy projects such as photovoltaic and wind power stations, providing reliable circuit control and short-circuit protection for new energy power delivery systems.

Several key operation and installation precautions must be followed for stable performance. First, the equipment is strictly designed for indoor use only, working environment temperature should range from -25℃ to 40℃, with no flammable, corrosive or dusty gas around. Second, operators must strictly follow interlock rules; never force manual unlocking or open the cabinet door in live status. Third, clean internal debris and check grounding conditions before installation and regular maintenance. Fourth, conduct periodic insulation testing and component inspection annually to eliminate potential hidden dangers.
With standardized production and customizable configuration, GAOBO’s KYN28-12 switchgear ensures stable, safe and intelligent power distribution for global medium-voltage engineering projects.